Anthem Genesis is the most avant-garde room correction software bachelor. Below is a complete user guide and recommendations from the Canticle squad to ensure yous get the best possible results of your measurements.
Install ARC Genesis
- Download and install the plan.
- Connect your estimator to the same network equally your ARC or PBK compatible audio device, or attach your reckoner and audio device using a USB cable.
- Start ARC Genesis. Select Auto mode and click Okay (merely displays the first time ARC is run).
- Cull Launch ARC.
- Choose your audio device.
- Configure measurements (tell ARC well-nigh your sound organization).
- Choose your microphone and measure your system.
- Upload your corrections and hear the difference ARC makes.
Taking Measurements with ARC Genesis
Proper microphone positioning is essential for good results. Multiple microphone positions are required to preclude standing waves or boundaries from skewing results. To achieve the best results with ARC Genesis, follow these uncomplicated rules.
- ALWAYS signal your microphone at the ceiling.
- ALWAYS identify the 1st position at your principal listening location. The 1st position is critical because it is used to set the level of the overall system.
- E'er place the mic acme most ear level (if you sit down when you heed, use the relative elevation of your ears when seated). The microphone, the listener'due south ears, and the speaker'southward acoustic centre (or tweeter if in doubt) should be at approximately the same height. If the consequence sounds tiresome or bright, a new feature of ARC Genesis is the ability to boost and cut deep bass and high frequencies in the "Adjust ARC Settings> Arrange Targets" bill of fare.
- WHENEVER POSSIBLE, make certain the chief listening position is a minimum of two to 3 feet (60 to ninety cm) from walls and other large hard surfaces. Delight annotation:
- We empathize that the location of the principal listening position is oftentimes not flexible.
- For best results when listening, a listener's ears should be away from whatsoever walls a minimum altitude of two to three feet (60 to 90cm).
- If the 1st mic position falls inside 2 to iii anxiety (60 to 90cm) grade a wall, high-backed furniture, or similar obstructions, it's of import to measure from a position as close to the listener'south head as possible. So place the first mic position just in front of where the listener's head would be. In this case, always place the 2nd through fifth positions the recommended distance from each other, fifty-fifty if this results in them being less than two to three feet (60 to 90cm) abroad from a wall. The resulting pattern may expect less like an 10 and more like a V or Thousand, and that'south okay.
- WHENEVER POSSIBLE, place the 2nd through fifth positions ii feet (60cm) from the 1st position. Up to three feet (90cm) is acceptable, only non usually necessary.
- WHENEVER POSSIBLE, place the 2nd through 5th positions symmetrically around the 1st position. Utilize an Ten pattern, with the 1st position in the centre of the 10, and each corner ii feet (60cm) from the center.
- WHENEVER POSSIBLE, vary the mic peak for the second through 5th positions, with ii measurements being 6 to 12-inches below the 1st position and the other two measurements 6 to 12-inches above the pinnacle of the 1st position. This method provides ARC with a more three-dimensional view of the room and its acoustic signature.
Other Considerations When Taking Measurements with ARC Genesis
- A shorter distance between mic positions is advised but for systems where ARC is being used exclusively for low-frequency corrections (subwoofers or speakers with active woofer systems), where the room is already well treated, or where there's simply one principal listening position. In these cases, consider varying the altitude between microphone positions by as little as ane pes (30cm).
Don't Brand These Common Mistakes!
- NEVER measure all five positions at the same location—the differences in the acoustic response at the five measurement locations are what allows ARC to understand the acoustic signature of your room.
- NEVER place the 2nd through fifth positions at the four corners of the room—don't do information technology! There doesn't need to exist much distance between microphone locations for ARC to understand a room'southward acoustic signature. Long distances between measurement positions adversely impact your final room corrections.
- WHENEVER POSSIBLE, do not place the 2nd through 5th positions further than 3 feet (90cm) away from the 1st position—a symmetrical pattern of spots effectually the first location is more important than putting the microphone at each listening position throughout the room.
Dealing With Subwoofers That Have Built-in Equalization or Room Correction
Nosotros've often heard, "Equalization is available for my subwoofer. Should I use the sub's congenital-in EQ when I am also using a receiver to correct the sub every bit part of a multi-channel system?" Since rooms and correction systems vary, the reply varies. If using MartinLogan or Paradigm subwoofers (with ARC or PBK built-in), results are often meliorate with the subwoofer'due south correction system is run earlier correcting the entire system. If the sub's EQ is not ARC or PBK based, it is usually best to disable the subwoofer's EQ before running ARC. When using ARC Genesis to correct the entire organization with your Canticle receiver or preamp, if the resulting target curves and calculated curves in the room correction software resemble each other, there is typically no reason to use the sub'south EQ. If the 2 curves differ significantly through a wide range (meaning the room correction software was not able to make the subwoofer fully match the target bend), enable the sub'southward EQ and rerun ARC to see if it helps.